The S/390 members of the buildfarm are showing failures indicating
that they're having trouble with the rint() calls I added yesterday.
There's no good reason for that, and I wonder if it is a compiler bug
similar to the one we worked around in
d9476b838. Try to fix it using
the same method as before, namely to store the result of rint() back
into a "double" variable rather than immediately converting to int64.
(This isn't entirely waving a dead chicken, since on machines with
wider-than-double float registers, the extra store forces a width
conversion. I don't know if S/390 is like that, but it seems worth
trying.)
In passing, merge duplicate ereport() calls in float8_timestamptz().
Per buildfarm.
result->day = weeks * 7 + days;
#ifdef HAVE_INT64_TIMESTAMP
+ secs = rint(secs * USECS_PER_SEC);
result->time = hours * ((int64) SECS_PER_HOUR * USECS_PER_SEC) +
mins * ((int64) SECS_PER_MINUTE * USECS_PER_SEC) +
- (int64) rint(secs * USECS_PER_SEC);
+ (int64) secs;
#else
result->time = hours * (double) SECS_PER_HOUR +
mins * (double) SECS_PER_MINUTE +