International Journal of Power Electronics and Drive System (IJPEDS)
Vol. 8, No. 1, March 2017, pp. 392~401
ISSN: 2088-8694, DOI: 10.11591/ijpeds.v8i1.pp392-401  392
Journal homepage: http://iaesjournal.com/online/index.php/IJPEDS
Modeling and Simulation of Grid Connected PV Generation
System Using Matlab/Simulink
Omar Mohammed Benaissa1
, Samir Hadjeri2
, Sid Ahmed Zidi3
1,2,3
Laboratory of Intelligent Control and Electrical Power System, DjillaliLiabes University, Sidi Bel Abbes, Algeria
Article Info ABSTRACT
Article history:
Received Oct 28, 2016
Revised Jan 03, 2016
Accepted Jan 13, 2017
This paper describes the Grid connected solar photovoltaique system using
DC-DC boost converter and the DC/AC inverter (VSC) to supplies electric
power to the utility grid. The model contains a representation of the main
components of the system that are two solar arrays of 100 kW, boost
converter and the grid side inverter. The paper starts with a system
description, in this part we have given a definition and a short overview of
every component used in this system and they are taken separately. The PV
cell model is easy, accurate, and takes external temperature and solar
radiation into consideration. It also proposes a maximum power point
tracking (MPPT) algorithm. The algorithm incorporated in a DC/DC
converter is used to track the maximum power of PV cell. Finally, the
DC/AC inverter (VSC) of three- level is used to regulate the ouput voltage of
DC/DC converter and connects the PV array to the grid. Simulation results
show how a solar radiation’s change can affect the power output of any PV
system, also they show the control performance and dynamic behavior of the
grid connected photovoltaic system.
Keyword:
Boost converter
Grid-connected
Matlab/Simulink
MPPT
Photovoltaic system
VSC inverter
Copyright © 2017 Institute of Advanced Engineering and Science.
All rights reserved.
Corresponding Author:
Omar Mohammed Benaissa,
Laboratory of Intelligent Control and Electrical Power System,
Djilali liabes University,
SidiBel Abbes, Algeria.
Email: omarioriquelme10@yahoo.fr
1. INTRODUCTION
Because energy resources and their utilization will be a prominent issue of this century, the
problems of natural resource depletion, environmental impacts, and the rising demand for new energy
resources have been discussed fervently in recent years [1].Grid-connected photovoltaic (PV) power systems
have been sustaining an exponential growth rate during the past decade. This steep growth is driven by a
growing concern about climate change, rebates and tax incentives, and reduction in PV system cost. The
main disadvantage of solar energy based electrical power supply is that power generation is not constant
throughout the day, as it always changes with atmospheric conditions [2]. Further, the efficiency of solar
energy conversion to electrical energy is very low, only in the range of 9-17%. Therefore, maximum power
point tracking (MPPT) is an essential part of a grid-tied solar PV system to ensurethat maximum available
power is always extracted out of the PV panel at all conditions and steered to the AC grid, considered as an
infinite sink of power ideally [3].This feature has an essential role in dynamic response andefficiency of the
photovoltaic system, in literature, different MPPT algorithms are introduced and among them the “Perturb
and Observe (P&O)” and “Incremental Conductance” are mostly used [4],[5], on the other hand, some
MPPTs are more rapid and accurate and thus more impressive, which need special design and familiarity
with specific subjects such as fuzzy logic [6], or neural network [7] methods.
Grid connected PV systems feed electricity directly to the electrical network, operating parallel to
the conventional electric source. The simplest grid-connected PV system contains a PV array and an inverter
IJPEDS ISSN: 2088-8694 
Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa)
393
unit used for residential purpose to generate clean electricity near the point of use [8]. One of the main
technical barriers that can ultimately limit further PV penetration is the fast variations in the PV system’s
output power induced by cloud transients. Such events are known to cause voltage fluctuations which may
lead to excessive operations of voltage regulation equipment and light flickering [9].
Solar irradiance variability, which can be easily recorded using a pyranometer and a data logger, is
used in numerous studies to assess the AC power injected into the grid by PV systems. But in reality, the two
variables are not perfectly proportional with one another, nor synchronized in time due to delays within the
inverter circuit elements and controls.
As a consequence, computer models that accurately simulate the dynamic behavior of PV systems
under moving clouds would thus be of high value. In this paper, a dynamic MATLAB/Simulink model of a
three phase grid-connected PV system that can be used to predict the deviations in AC power output under
variable solar irradiance is presented. The commonly used perturb-and-observe technique for Maximum
Power Point Tracking (MPPT) is used in the present model. Figure 1 shows a typical utility interactive PV
system, it is found that the deviation between solar radiation and output power variability that may be caused
by the MPPT and buffer capacitor is minimal and can often be neglected. As a result, the variations in solar
irradiance can be considered as a good indication of power fluctuations.
Figure 1. Utility interactive pv system
2. SYSTEM DESCRIPTION
Figure 2 shows two PV arrays of 100kW connected to a 25kV grid via two DC-DC boost converters
and a three-phase three-level Voltage Source Converter (VSC). Maximum Power Point Tracking (MPPT) is
implemented in the boost converter by means of a Simulink model using the 'Perturb & Observe' technique.
The proposed model contains the following components:
a. Two PV arrays delivering a maximum of 200 kW at 1000 W/m² sun irradiance.
b. Two DC-DC boost converters (orange block) that are used to increase the voltage output of PV1 and
PV2 to 500 V DC.
c. Three-level three-phase VSC inverter (blue blocks) that is used to convert the DC voltage delivered by
the arrays of (500 V) to an AC voltage of 260 V and also to keep a unity power factor.
d. Capacitor Banks of 20 kVar used to filter the harmonics produced by the VSC.
e. A three-phase coupling transformer of 200 kVA. And 260/25kV.
f. Utility grid.
 ISSN: 2088-8694
IJPEDS Vol. 8, No. 1, March 2017 : 392 – 401
394
Figure 2. Whole PV grid-connected system
2.1. The photovoltaic generator
The PV system represented in this paper consists of two photovoltaic arrays work in parallel that are
PV1 array and PV2 array. The 100-kW PV1 array « SunPower (SPR-305) », consists of 66 strings of 5
series-connected 305.2W modules connected in parallel (66*5*305.2 W= 100.7 kW).
Manufacturer specifications for the module « SPR-305 » are listed in Table 1. The PV array block
has one input that allow you varying sun irradiance (input 1 in W/m²). The irradiance profile is defined by a
Signal Builder block which is connected to the PV array inputs. The characteristics I-V and P-V of one
module SunPowerSPR-305-WHT type are represented in Figure 3.
Table 1. Specifications of « SunPower (SPR-305) » PV-array
Model name SunPower SPR-305-WHT
No. of cells 96 in series
Open circuit voltage (Voc) 64.2 V
Short circuit current (Isc) 5.96 A
Maximum Power Voltage(Vmp) 54.7 V
Maximum Power Current (Imp) 5.58 A
Figure 3. The characteristics I-V and P-V of one module SunPower SPR-305-WHT type
IJPEDS ISSN: 2088-8694 
Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa)
395
The characteristics of PV1 array are shown below:
Figure 4. The Characteristics I-V and P-V of the PV1 array
However the PV2 array of 100 kW, uses 488 panels « Kyocera KD205GX-LP », consists of 61
strings of 8 series-connected 205 W modules connected in parallel (61*8*205 W= 100.04 kW).
Manufacturer specifications for the module « Kyocera KD205GX-LP »are listed in the Table 2:
Table 2. Specifications of « Kyocera KD205GX-LP » PV-array
Model name Kyocera KD205GX-LP
No. of cells 54 in series
Open circuit voltage (Voc) 33.2 V
Short circuit current (Isc) 8.359 A
Maximum Power Voltage(Vmp) 26.6 V
Maximum Power Current (Imp) 7.7 A
The characteristics I-V and P-V of one module Kyocera KD205GX-LP type are represented in
Figure 5.
Figure 5.The characteristics I-V and P-V of one module Kyocera KD205GX-LP type
The characteristics of PV2 array are shown below:
 ISSN: 2088-8694
IJPEDS Vol. 8, No. 1, March 2017 : 392 – 401
396
Figure 6. The Characteristics I-V and P-V of the PV2 array
2.2. Boost converter
It is implemented in this proposed system by using a diode and a MOSFET. In the boost converter
the average output current is less then the average inductor current. and a much higher rms current would
flow through the filter capacitor dueto this reason a large value of the inductor and filter capacitor is required
than those of buck converter [10].When the MOSFET switch is ON, the current through the inductor
increases and the inductor starts to store energy. When the MOSFET switch is closed, the energy stored in
the inductor starts dissipating. The current from the voltage source and the inductor flows through the fly
back Diode D to the load. Thus the average voltage across the load is greater than the input voltage and is
determined with help of the duty cycle of the gate pulse to the MOSFET switch [12].
Figure 7 shows the schematic diagram for the boost converter used in this research work to step up
the PV output voltage to a higher level suitable for the DC/AC inverter operation that connected to the utility
grid [11].
Figure 7. Boost converter
0
1
S
V
V
D


(1)
on
SW
T
D
T
 (2)
SW on off
T T T
  (3)
Where:
a. S
V Is source voltage
b. 0
V Is the output voltage of the converter
c. DIs the duty cycle
IJPEDS ISSN: 2088-8694 
Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa)
397
d.
1
SW
SW
F
T
 Is switching frequency of the converter
e. on
T Is on time period of the semiconductor switch
f. off
T Is off time period of the semiconductor switch
In our model, we have two boost converters used to increase the DC voltage delivered by the two
PV1 and PV2 arrays to 500V. The two boost converters use the MPPT controller that automatically varies the
duty cycle to generate the voltage required to extract the maximum power.
2.3. Maximumpower utilization of photovoltaic (PV) power sources
At any given time, to extract the maximum power generated by a solar cell, the solar System has to
be equipped with a maximum power point tracker (MPPT). It helps to operate the PV system at the
maximum output power point for a given set of conditions, thereby maximizing the array efficiency. The
MPPT does this by constantly controlling the PV voltage or current independently regardless of the load
connected. The MPPT technology is commonly implemented in the DC-DC converters, but due to
technological advancements in recent times, now it can also be implemented in the DC-AC inverters.
Although, several MPPT methods are available, the most commonly practiced is Perturb and Observe so it
will be used in our present study [13]-[14].
2.3.1. Perturb-and-observe (P&O) method
The perturb-and-observe (P&O) algorithm is the most commonly used in practice for MPP tracking.
It is based on the fact that as the voltage is perturbed and the rate of change of power is observed. Based on
the sign (positive or negative) of the derivative , the voltage value is increased or decreased to reach MPP,
thereby yielding a zero, derivative. As the nature of this algorithm is absolutely based on perturbation, one
can notice some oscillations even after the MPP is reached [13],[15].
Figure 8. Power vs voltage curve showing MPP
2.4. VSC Inverter
PV modules generate direct current (DC) and voltage. However, to feed the electricity to the grid,
alternating current (AC) current and (AC) voltage are needed. Inverters are the equipment used to convert
DC to AC. In addition, they can be in charge of keeping the operating point of the PV array at the MPP. This
is usually done with computational MPP tracking algorithms. There are different inverter configurations
depending on how the PV modules are connected to the inverter.
The VSC converts the 500 V DC link voltages to 260 V AC and keeps power factor at unity. The
VSC control system consists of two control loops:
a. An external control loop which regulates DC link voltage to +/- 250 V.
b. An internal control loop which regulates grid currents (active and reactive) current components.
c. The control system uses a sample time of 100 microseconds for voltage and current controllers.
Boost and VSC converters with pulse generators use a fast sample time of 1 microsecond in order to
get an appropriate resolution of PWM waveforms [16].
 ISSN: 2088-8694
IJPEDS Vol. 8, No. 1, March 2017 : 392 – 401
398
3. SIMULATION RESULTS AND DISCUSSION
Simulation starts with standard test conditions (25 °C, 1000 W/m²). From t=0 sec to t=0.05 sec, the
pulses for boost converters and VSC inverter are blocked. The voltage of PV1 array correspond to the open
circuit voltage (5 panels in Series * Voc = 5 * 64.2 = 321 V), and for PV2 array (8 panels in Séries *Voc =8
* 33.2 = 265.6 V) (see Figure 9). At this time the VSC inverter of three-level functions as an uncontrolled
rectifier (diode) and the DC capacitors are charged over 500 V (Figure 11).
At t = 0.05 s, boost converter and VSC inverter are unlocked. The DC voltage is set at Vd = 500V
(see Figure 11). The duty cycles of the two boost converter equal to 0.5 and 0.6 respectively (see Figure 10)
irradiance is set at 1000 W/m2 as shown in Figure 12. The nominal speed is reached at t = 0.25s, the voltage
generated by the array PV1 is VPV1 = (1-D1) * Vd= (1-0.5) * 500 = 250 V, while the voltage generated by the
array PV2 is VPV2 = (1-D2)*Vd = (1-0.6) * 500 = 200 V.
Figure 9. Voltage generated by PV1 and PV2 arrays Figure 10. Duty cycles of PV1 and PV2 arrays
Figure 11. DC link voltage Vd Figure 12. Irradiance of the PV1 and PV2 arrays
The power generated by arrays PV1 and PV2 are on the order of 97 kilowatts and 98 kilowatts
respectively, while the maximum powers with irradiance of 1000W/ m² are estimated at 100.7 kilowatts to
100.04 kilowatts (see Figure 13). It is important to note that the voltage and current of phase A at 25 kV
busbar are in phase (power factor equals to 1) as shown in Figure 14.
IJPEDS ISSN: 2088-8694 
Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa)
399
Figure 13. The powers generated by the PV1 and
PV2 arrays
Figure 14. Current and voltage injected into the grid
At t = 0.4 s both MPPT controls are enabled. MPPT1 controller starts controlling the voltage
generated by PV1 by acting on the duty cycle of the first boost converter in order to extract the maximum
power. The maximum power of the first PV array (100.7 kilowatts) is obtained when the duty cycle D1
equals to 0.453. At t = 0.6 s, the voltage of the array PV1=274 V as expected from the specifications of the
PV array (N_série*Vmp = 5 * 54.7 = 273.5 V).
From t = 0.7 s to t = 1.2 s, the irradiance Ir1 decreases linearly from 1000 W/m² to 250 W/m². From
time t=1.1, the irradiance Ir2 also decreases linearly from 1000 W/m² to 250 W/m² (Figure 16). Both MPPT
controllers continue tracking the maximum power delivered by each PV array. At t = 1.2 s when the
irradiance Ir1 reaches the value of 250 W/m², the duty cycle D1 is around 0.485. The corresponding voltage
and power are 255 V and 22.6 kilowatts respectively. For the second PV array, the irradiance Ir2 reaches the
value of 250 W/m² at t = 1.65 s, where the duty cycle D2=0.6.
Note that tracking the maximum power point by the MMPT controller is ensured even when the
irradiance changes rapidly. From t = 1.5 s to t = 3 s various changes of the irradiance Ir1 and Ir2 are applied to
illustrate the good performance of the MPPT controller.
Figure 15. Power generated by the PV1 and PV2
arrays
Figure 16. Irradiance of the two arrays
 ISSN: 2088-8694
IJPEDS Vol. 8, No. 1, March 2017 : 392 – 401
400
Figure 17. Duty cycles of the PV1 and PV2 arrays Figure 18. Voltage generated by the PV1 and PV2
arrays
Figure 19 shows the power injected into the grid. From t = 0 s to t = 0.05 s the power injected into
the grid is growing because the pulses of boost converter and VSC inverter are blocked. At t = 0.05s the
pulses are enabled, the power injected into the grid is 195 kW.
From t = 0.2 s to t = 0.75 s the irradiance is 1000W / m², while the injected power reaches its
maximum value. From t = 0.75 s to t = 2.75 s several variations in the irradiance lead to change the power
injected into the grid to stabilize at 2.75 s and takes the value of 200 kilowatts.
Figure 19. Power injected into the grid
4. CONCLUSION
This paper presents the modeling and simulation of grid connected PV system with Perturb and
Observe MPPT Algorithm to inject the power extracted from a photovoltaic array and obtain unitary power
factor in varying weather conditions. According to the results obtained from the simulation, we can say that it
is essential to operate the system at the MPP (Maximum Power Point) of a PV array, in other words we
should always extract the maximum power from the PV module by modulating the duty cycle of the boost
converter in order to enhance the power injected into the grid, otherwise the PV array is not fully exploited
which consecontly is reflected by a higher losses in the energy transferred from the PV array to the utility
grid. Also the Pulse width modulation (PWM) technique has been developed beside inverters. So that we can
obtain a sinusoidal waveform at the output of the inverter and the total harmonic distortion (THD) of the
output voltage can be reduced.The results confirm the adequate performance of whole designed control.
REFERENCES
[1] K. S. Srikanth, “A Three Phase Multi Level Converter for Grid Connected PV System,” International Journal of
Power Electronics and Drive System (IJPEDS), vol/issue: 5(1), pp. 71-75, 2014.
[2] M. C. Mira, et al., “Boost Converter With Combined Control Loop for a Stand-Alone Photovolainc Battery Charge
System,” IEEE 14th Workshop On Control and Modeling Power electronics, 2013.
[3] “Photovoltaic Cell Conversion Efficiency,” U.S. Department of Energy, Retrieved, 19 May 2012.
[4] D. Sera, et al., “On the Perturb-and-Observe and Incremental Conductance MPPT Methods for PV Systems,” IEEE
Journal of Photovoltaics, vol/issue: 3(3), pp. 1070-1078, 2013.
IJPEDS ISSN: 2088-8694 
Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa)
401
[5] F. Liu, et al., “Variable Step Size INC MPPT Method for PV Sytems,” IEEE Transactions on Industrial
Electronics, vol/issue: 55(7), 2008.
[6] T. F. Wu, et al., “A Fuzzy Logic-Controlled Single Stage Converter for PV-Powred Lighting System
Applications,” IEEE Transactions on Industrial Electronics, vol/issue: 47(2), pp. 287–296, 2000.
[7] M. Veerachary, et al., “Neural-Network Based Maximum Power Point Tracking of Coupled-Iductor Interleaved-
Boot Converter Supplied PV System Using Fuzzy Controller,” IEEE Transactions on Industrial Electronics,
vol/issue: 50(4), pp. 749-758, 2003.
[8] P. H. Zope, et al, “Performance and Simulation Analysis of Single-Phase Grid Connected PV System Based on Z-
Source Inverter,” in International conference on Power Electronics, Drives and Energy System, 2010.
[9] S. Li, et al, “A Novel Maximum Power Point Tracking Control Method With Variable Weather Parameters for
Photovoltaic Systems,” (ELSEVIER), Solar Energy, vol. 97, pp. 529-536, 2013.
[10] A. A. Siddik and M. Shangeetha, “Implimentation of Fuzzy Logic Controller in photovoltaic Power generation
using Boost converter and Boost Inverter,”International Journal of Power Electronics and Drive System (IJPEDS),
vol/issue: 2(3), pp. 249-256, 2012.
[11] G. E. Saady, et al., “Performance of Photovoltaic Water Pumping System under Different MPPT Algorithms,” in
17th International Middle –East power system Conference, 2015.
[12] R. Teodorescu and M. Liserre, “Power Electronics for Renewable Energy,” Slides presented at the course PERES,
2006.
[13] J. J. Nedumgatt, et al., “Perturb and Observe MPPT Algorithm for Solar PVSystems-Modeling and Simulation,” in
Annual IEEE India Conference, pp. 1-6, 2011.
[14] K. Manohar and P. S. Rani, “MPPT and Simulation for a Grid-Connected Photovoltaic System and Fault Analysis,”
International Journal of Engineering And Science (IJES), pp. 158-166, 2013.
[15] M. D Singh and K. B Khanchandani, “Power Electronics,” Tata Mcgraw Hill publishers, 2nd edition, pp. 135-670,
2011.
[16] J. Kasera, et al, “Design of grid connected Photovoltaic System Employing Incrimental Conductance MPPT
Algorithm,” Journal of Electrical Engeneering.

More Related Content

PDF
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
PDF
14 9737 lightning paper id 0005 edit septian
PDF
IRJET - Optimal Scheduling of Solar Wind Bio-Mass Systems and Evaluating the ...
PDF
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...
PDF
Photovoltaic Emulator for Grid-connected Quasi-Z-Sorce Inverter
PDF
Development of Load Control Algorithm for PV Microgrid
PDF
Intelligent controller based power quality improvement of microgrid integrati...
PDF
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
14 9737 lightning paper id 0005 edit septian
IRJET - Optimal Scheduling of Solar Wind Bio-Mass Systems and Evaluating the ...
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...
Photovoltaic Emulator for Grid-connected Quasi-Z-Sorce Inverter
Development of Load Control Algorithm for PV Microgrid
Intelligent controller based power quality improvement of microgrid integrati...
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...

What's hot (20)

PDF
L01052101108
PDF
Fuzzy logic based MPPT technique for a single phase Grid connected PV system ...
PDF
1 s2.0-s187661021301103 x-main
PDF
C011141018
PDF
Performance Investigation of Grid Connected Photovoltaic System Modelling Bas...
PDF
Modelling of fuzzy logic controller for variable step mppt in photovoltaic sy...
DOCX
Maximum Power Point Tracking Method for Single Phase Grid Connected PV System...
PDF
Design of Power Inverter for Photovoltaic System
PDF
Simulation of various DC-DC converters for photovoltaic system
PPTX
Simulation of dcdc converter
PDF
IRJET- Cascaded Multilevel Inverter with MPPT for Grid Connected PV System
PDF
Design & Analysis of Grid Connected Photovoltaic System
PDF
Development and Analysis of Fuzzy Control for MPPT Based Photovoltaic System
PDF
Comparison study of lead-acid and lithium-ıon batteries for solar photovoltai...
PDF
Comparison of P&O and fuzzy MPPT Methods for Photovoltaic System
PDF
A Novel Approach on Photovoltaic Technologies for Power Injection in Grid Usi...
PDF
A Flexible AC Distribution System for a Microgrid with a Photovoltaic System ...
PDF
Measurement and Analysis of Power in Hybrid System
PDF
Energy Storage Management in Grid Connected Solar Photovoltaic System
PDF
Fuzzy Logic based Maximum Power Point Tracker in Photovoltaic Cell
L01052101108
Fuzzy logic based MPPT technique for a single phase Grid connected PV system ...
1 s2.0-s187661021301103 x-main
C011141018
Performance Investigation of Grid Connected Photovoltaic System Modelling Bas...
Modelling of fuzzy logic controller for variable step mppt in photovoltaic sy...
Maximum Power Point Tracking Method for Single Phase Grid Connected PV System...
Design of Power Inverter for Photovoltaic System
Simulation of various DC-DC converters for photovoltaic system
Simulation of dcdc converter
IRJET- Cascaded Multilevel Inverter with MPPT for Grid Connected PV System
Design & Analysis of Grid Connected Photovoltaic System
Development and Analysis of Fuzzy Control for MPPT Based Photovoltaic System
Comparison study of lead-acid and lithium-ıon batteries for solar photovoltai...
Comparison of P&O and fuzzy MPPT Methods for Photovoltaic System
A Novel Approach on Photovoltaic Technologies for Power Injection in Grid Usi...
A Flexible AC Distribution System for a Microgrid with a Photovoltaic System ...
Measurement and Analysis of Power in Hybrid System
Energy Storage Management in Grid Connected Solar Photovoltaic System
Fuzzy Logic based Maximum Power Point Tracker in Photovoltaic Cell
Ad

Similar to Modeling and Simulation of Grid Connected PV Generation System Using Matlab/Simulink (20)

PDF
IRJET- Design Simulation and Control of Utility Grid Connected Solar Photovol...
PDF
IRJET- Maximum Power Point Technique (MPPT) for PV System based on Improv...
PDF
Modeling Simulation and Design of Photovoltaic Array with MPPT Control Techni...
PDF
A. attou ajbas issn 1991-8178-pv mppt
PDF
Performance of Maximum Power Point Tracking Algorithm based Photovoltaic Arra...
PDF
IRJET- High Accurate Sensorless Dual Axis Solar Tracking System Controlle...
PPTX
THREE PHASE GRID CONNECTED SOLAR PV SYSTEM
PDF
Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...
PDF
Modeling and Analysis of a Maximum Power Point Tracking Control for Double St...
PDF
Particle Swarm Optimization PSO Algorithm Based MPPT for PV System Operating ...
PDF
Review of Maximum Power Point Tracking Based PV Array to Produce Electric Energy
PDF
An Overview of MPPT for Photovoltaic Panels Using Various Artificial Intellig...
PDF
PV Hybrid System with DSTATCOM for Residential Applications
PDF
“Performance Analysis of Induction Motor Fed from Hybrid Micro grid system”
PDF
Grid Connected Solar Photovoltaic Array with MPPT Matlab Simulation
PDF
IRJET- Photovoltaic 10MW Power Plant Simulation & Design using Mathwork &...
PDF
Electric Vehicle as an Energy Storage for Grid Connected Solar Power System
PDF
Modeling of Solar PV system under Partial Shading using Particle Swarm Optimi...
PDF
Perturb and observe maximum power point tracking for photovoltaic cell
PDF
Attou. photovoltaic grid Boost Converter
IRJET- Design Simulation and Control of Utility Grid Connected Solar Photovol...
IRJET- Maximum Power Point Technique (MPPT) for PV System based on Improv...
Modeling Simulation and Design of Photovoltaic Array with MPPT Control Techni...
A. attou ajbas issn 1991-8178-pv mppt
Performance of Maximum Power Point Tracking Algorithm based Photovoltaic Arra...
IRJET- High Accurate Sensorless Dual Axis Solar Tracking System Controlle...
THREE PHASE GRID CONNECTED SOLAR PV SYSTEM
Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...
Modeling and Analysis of a Maximum Power Point Tracking Control for Double St...
Particle Swarm Optimization PSO Algorithm Based MPPT for PV System Operating ...
Review of Maximum Power Point Tracking Based PV Array to Produce Electric Energy
An Overview of MPPT for Photovoltaic Panels Using Various Artificial Intellig...
PV Hybrid System with DSTATCOM for Residential Applications
“Performance Analysis of Induction Motor Fed from Hybrid Micro grid system”
Grid Connected Solar Photovoltaic Array with MPPT Matlab Simulation
IRJET- Photovoltaic 10MW Power Plant Simulation & Design using Mathwork &...
Electric Vehicle as an Energy Storage for Grid Connected Solar Power System
Modeling of Solar PV system under Partial Shading using Particle Swarm Optimi...
Perturb and observe maximum power point tracking for photovoltaic cell
Attou. photovoltaic grid Boost Converter
Ad

More from International Journal of Power Electronics and Drive Systems (20)

PDF
Adaptive backstepping controller design based on neural network for PMSM spee...
PDF
Classification and direction discrimination of faults in transmission lines u...
PDF
Integration of artificial neural networks for multi-source energy management ...
PDF
Rotating blade faults classification of a rotor-disk-blade system using artif...
PDF
Artificial bee colony algorithm applied to optimal power flow solution incorp...
PDF
Soft computing and IoT based solar tracker
PDF
Comparison of roughness index for Kitka and Koznica wind farms
PDF
Primary frequency control of large-scale PV-connected multi-machine power sys...
PDF
Performance of solar modules integrated with reflector
PDF
Generator and grid side converter control for wind energy conversion system
PDF
Wind speed modeling based on measurement data to predict future wind speed wi...
PDF
Comparison of PV panels MPPT techniques applied to solar water pumping system
PDF
Prospect of renewable energy resources in Bangladesh
PDF
A novel optimization of the particle swarm based maximum power point tracking...
PDF
Voltage stability enhancement for large scale squirrel cage induction generat...
PDF
Electrical and environmental parameters of the performance of polymer solar c...
PDF
Short and open circuit faults study in the PV system inverter
PDF
A modified bridge-type nonsuperconducting fault current limiter for distribut...
PDF
The new approach minimizes harmonics in a single-phase three-level NPC 400 Hz...
PDF
Comparison of electronic load using linear regulator and boost converter
Adaptive backstepping controller design based on neural network for PMSM spee...
Classification and direction discrimination of faults in transmission lines u...
Integration of artificial neural networks for multi-source energy management ...
Rotating blade faults classification of a rotor-disk-blade system using artif...
Artificial bee colony algorithm applied to optimal power flow solution incorp...
Soft computing and IoT based solar tracker
Comparison of roughness index for Kitka and Koznica wind farms
Primary frequency control of large-scale PV-connected multi-machine power sys...
Performance of solar modules integrated with reflector
Generator and grid side converter control for wind energy conversion system
Wind speed modeling based on measurement data to predict future wind speed wi...
Comparison of PV panels MPPT techniques applied to solar water pumping system
Prospect of renewable energy resources in Bangladesh
A novel optimization of the particle swarm based maximum power point tracking...
Voltage stability enhancement for large scale squirrel cage induction generat...
Electrical and environmental parameters of the performance of polymer solar c...
Short and open circuit faults study in the PV system inverter
A modified bridge-type nonsuperconducting fault current limiter for distribut...
The new approach minimizes harmonics in a single-phase three-level NPC 400 Hz...
Comparison of electronic load using linear regulator and boost converter

Recently uploaded (20)

DOCX
573137875-Attendance-Management-System-original
PPTX
Geodesy 1.pptx...............................................
PPTX
UNIT 4 Total Quality Management .pptx
PDF
SM_6th-Sem__Cse_Internet-of-Things.pdf IOT
PPTX
Welding lecture in detail for understanding
PDF
Model Code of Practice - Construction Work - 21102022 .pdf
PPTX
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
PPT
CRASH COURSE IN ALTERNATIVE PLUMBING CLASS
PPTX
Sustainable Sites - Green Building Construction
PPT
Mechanical Engineering MATERIALS Selection
PPTX
MCN 401 KTU-2019-PPE KITS-MODULE 2.pptx
PDF
Evaluating the Democratization of the Turkish Armed Forces from a Normative P...
PDF
Operating System & Kernel Study Guide-1 - converted.pdf
PDF
Embodied AI: Ushering in the Next Era of Intelligent Systems
PPTX
FINAL REVIEW FOR COPD DIANOSIS FOR PULMONARY DISEASE.pptx
PPTX
Internet of Things (IOT) - A guide to understanding
PPT
Project quality management in manufacturing
PPTX
CH1 Production IntroductoryConcepts.pptx
PDF
Automation-in-Manufacturing-Chapter-Introduction.pdf
PDF
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
573137875-Attendance-Management-System-original
Geodesy 1.pptx...............................................
UNIT 4 Total Quality Management .pptx
SM_6th-Sem__Cse_Internet-of-Things.pdf IOT
Welding lecture in detail for understanding
Model Code of Practice - Construction Work - 21102022 .pdf
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
CRASH COURSE IN ALTERNATIVE PLUMBING CLASS
Sustainable Sites - Green Building Construction
Mechanical Engineering MATERIALS Selection
MCN 401 KTU-2019-PPE KITS-MODULE 2.pptx
Evaluating the Democratization of the Turkish Armed Forces from a Normative P...
Operating System & Kernel Study Guide-1 - converted.pdf
Embodied AI: Ushering in the Next Era of Intelligent Systems
FINAL REVIEW FOR COPD DIANOSIS FOR PULMONARY DISEASE.pptx
Internet of Things (IOT) - A guide to understanding
Project quality management in manufacturing
CH1 Production IntroductoryConcepts.pptx
Automation-in-Manufacturing-Chapter-Introduction.pdf
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf

Modeling and Simulation of Grid Connected PV Generation System Using Matlab/Simulink

  • 1. International Journal of Power Electronics and Drive System (IJPEDS) Vol. 8, No. 1, March 2017, pp. 392~401 ISSN: 2088-8694, DOI: 10.11591/ijpeds.v8i1.pp392-401  392 Journal homepage: http://iaesjournal.com/online/index.php/IJPEDS Modeling and Simulation of Grid Connected PV Generation System Using Matlab/Simulink Omar Mohammed Benaissa1 , Samir Hadjeri2 , Sid Ahmed Zidi3 1,2,3 Laboratory of Intelligent Control and Electrical Power System, DjillaliLiabes University, Sidi Bel Abbes, Algeria Article Info ABSTRACT Article history: Received Oct 28, 2016 Revised Jan 03, 2016 Accepted Jan 13, 2017 This paper describes the Grid connected solar photovoltaique system using DC-DC boost converter and the DC/AC inverter (VSC) to supplies electric power to the utility grid. The model contains a representation of the main components of the system that are two solar arrays of 100 kW, boost converter and the grid side inverter. The paper starts with a system description, in this part we have given a definition and a short overview of every component used in this system and they are taken separately. The PV cell model is easy, accurate, and takes external temperature and solar radiation into consideration. It also proposes a maximum power point tracking (MPPT) algorithm. The algorithm incorporated in a DC/DC converter is used to track the maximum power of PV cell. Finally, the DC/AC inverter (VSC) of three- level is used to regulate the ouput voltage of DC/DC converter and connects the PV array to the grid. Simulation results show how a solar radiation’s change can affect the power output of any PV system, also they show the control performance and dynamic behavior of the grid connected photovoltaic system. Keyword: Boost converter Grid-connected Matlab/Simulink MPPT Photovoltaic system VSC inverter Copyright © 2017 Institute of Advanced Engineering and Science. All rights reserved. Corresponding Author: Omar Mohammed Benaissa, Laboratory of Intelligent Control and Electrical Power System, Djilali liabes University, SidiBel Abbes, Algeria. Email: [email protected] 1. INTRODUCTION Because energy resources and their utilization will be a prominent issue of this century, the problems of natural resource depletion, environmental impacts, and the rising demand for new energy resources have been discussed fervently in recent years [1].Grid-connected photovoltaic (PV) power systems have been sustaining an exponential growth rate during the past decade. This steep growth is driven by a growing concern about climate change, rebates and tax incentives, and reduction in PV system cost. The main disadvantage of solar energy based electrical power supply is that power generation is not constant throughout the day, as it always changes with atmospheric conditions [2]. Further, the efficiency of solar energy conversion to electrical energy is very low, only in the range of 9-17%. Therefore, maximum power point tracking (MPPT) is an essential part of a grid-tied solar PV system to ensurethat maximum available power is always extracted out of the PV panel at all conditions and steered to the AC grid, considered as an infinite sink of power ideally [3].This feature has an essential role in dynamic response andefficiency of the photovoltaic system, in literature, different MPPT algorithms are introduced and among them the “Perturb and Observe (P&O)” and “Incremental Conductance” are mostly used [4],[5], on the other hand, some MPPTs are more rapid and accurate and thus more impressive, which need special design and familiarity with specific subjects such as fuzzy logic [6], or neural network [7] methods. Grid connected PV systems feed electricity directly to the electrical network, operating parallel to the conventional electric source. The simplest grid-connected PV system contains a PV array and an inverter
  • 2. IJPEDS ISSN: 2088-8694  Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa) 393 unit used for residential purpose to generate clean electricity near the point of use [8]. One of the main technical barriers that can ultimately limit further PV penetration is the fast variations in the PV system’s output power induced by cloud transients. Such events are known to cause voltage fluctuations which may lead to excessive operations of voltage regulation equipment and light flickering [9]. Solar irradiance variability, which can be easily recorded using a pyranometer and a data logger, is used in numerous studies to assess the AC power injected into the grid by PV systems. But in reality, the two variables are not perfectly proportional with one another, nor synchronized in time due to delays within the inverter circuit elements and controls. As a consequence, computer models that accurately simulate the dynamic behavior of PV systems under moving clouds would thus be of high value. In this paper, a dynamic MATLAB/Simulink model of a three phase grid-connected PV system that can be used to predict the deviations in AC power output under variable solar irradiance is presented. The commonly used perturb-and-observe technique for Maximum Power Point Tracking (MPPT) is used in the present model. Figure 1 shows a typical utility interactive PV system, it is found that the deviation between solar radiation and output power variability that may be caused by the MPPT and buffer capacitor is minimal and can often be neglected. As a result, the variations in solar irradiance can be considered as a good indication of power fluctuations. Figure 1. Utility interactive pv system 2. SYSTEM DESCRIPTION Figure 2 shows two PV arrays of 100kW connected to a 25kV grid via two DC-DC boost converters and a three-phase three-level Voltage Source Converter (VSC). Maximum Power Point Tracking (MPPT) is implemented in the boost converter by means of a Simulink model using the 'Perturb & Observe' technique. The proposed model contains the following components: a. Two PV arrays delivering a maximum of 200 kW at 1000 W/m² sun irradiance. b. Two DC-DC boost converters (orange block) that are used to increase the voltage output of PV1 and PV2 to 500 V DC. c. Three-level three-phase VSC inverter (blue blocks) that is used to convert the DC voltage delivered by the arrays of (500 V) to an AC voltage of 260 V and also to keep a unity power factor. d. Capacitor Banks of 20 kVar used to filter the harmonics produced by the VSC. e. A three-phase coupling transformer of 200 kVA. And 260/25kV. f. Utility grid.
  • 3.  ISSN: 2088-8694 IJPEDS Vol. 8, No. 1, March 2017 : 392 – 401 394 Figure 2. Whole PV grid-connected system 2.1. The photovoltaic generator The PV system represented in this paper consists of two photovoltaic arrays work in parallel that are PV1 array and PV2 array. The 100-kW PV1 array « SunPower (SPR-305) », consists of 66 strings of 5 series-connected 305.2W modules connected in parallel (66*5*305.2 W= 100.7 kW). Manufacturer specifications for the module « SPR-305 » are listed in Table 1. The PV array block has one input that allow you varying sun irradiance (input 1 in W/m²). The irradiance profile is defined by a Signal Builder block which is connected to the PV array inputs. The characteristics I-V and P-V of one module SunPowerSPR-305-WHT type are represented in Figure 3. Table 1. Specifications of « SunPower (SPR-305) » PV-array Model name SunPower SPR-305-WHT No. of cells 96 in series Open circuit voltage (Voc) 64.2 V Short circuit current (Isc) 5.96 A Maximum Power Voltage(Vmp) 54.7 V Maximum Power Current (Imp) 5.58 A Figure 3. The characteristics I-V and P-V of one module SunPower SPR-305-WHT type
  • 4. IJPEDS ISSN: 2088-8694  Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa) 395 The characteristics of PV1 array are shown below: Figure 4. The Characteristics I-V and P-V of the PV1 array However the PV2 array of 100 kW, uses 488 panels « Kyocera KD205GX-LP », consists of 61 strings of 8 series-connected 205 W modules connected in parallel (61*8*205 W= 100.04 kW). Manufacturer specifications for the module « Kyocera KD205GX-LP »are listed in the Table 2: Table 2. Specifications of « Kyocera KD205GX-LP » PV-array Model name Kyocera KD205GX-LP No. of cells 54 in series Open circuit voltage (Voc) 33.2 V Short circuit current (Isc) 8.359 A Maximum Power Voltage(Vmp) 26.6 V Maximum Power Current (Imp) 7.7 A The characteristics I-V and P-V of one module Kyocera KD205GX-LP type are represented in Figure 5. Figure 5.The characteristics I-V and P-V of one module Kyocera KD205GX-LP type The characteristics of PV2 array are shown below:
  • 5.  ISSN: 2088-8694 IJPEDS Vol. 8, No. 1, March 2017 : 392 – 401 396 Figure 6. The Characteristics I-V and P-V of the PV2 array 2.2. Boost converter It is implemented in this proposed system by using a diode and a MOSFET. In the boost converter the average output current is less then the average inductor current. and a much higher rms current would flow through the filter capacitor dueto this reason a large value of the inductor and filter capacitor is required than those of buck converter [10].When the MOSFET switch is ON, the current through the inductor increases and the inductor starts to store energy. When the MOSFET switch is closed, the energy stored in the inductor starts dissipating. The current from the voltage source and the inductor flows through the fly back Diode D to the load. Thus the average voltage across the load is greater than the input voltage and is determined with help of the duty cycle of the gate pulse to the MOSFET switch [12]. Figure 7 shows the schematic diagram for the boost converter used in this research work to step up the PV output voltage to a higher level suitable for the DC/AC inverter operation that connected to the utility grid [11]. Figure 7. Boost converter 0 1 S V V D   (1) on SW T D T  (2) SW on off T T T   (3) Where: a. S V Is source voltage b. 0 V Is the output voltage of the converter c. DIs the duty cycle
  • 6. IJPEDS ISSN: 2088-8694  Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa) 397 d. 1 SW SW F T  Is switching frequency of the converter e. on T Is on time period of the semiconductor switch f. off T Is off time period of the semiconductor switch In our model, we have two boost converters used to increase the DC voltage delivered by the two PV1 and PV2 arrays to 500V. The two boost converters use the MPPT controller that automatically varies the duty cycle to generate the voltage required to extract the maximum power. 2.3. Maximumpower utilization of photovoltaic (PV) power sources At any given time, to extract the maximum power generated by a solar cell, the solar System has to be equipped with a maximum power point tracker (MPPT). It helps to operate the PV system at the maximum output power point for a given set of conditions, thereby maximizing the array efficiency. The MPPT does this by constantly controlling the PV voltage or current independently regardless of the load connected. The MPPT technology is commonly implemented in the DC-DC converters, but due to technological advancements in recent times, now it can also be implemented in the DC-AC inverters. Although, several MPPT methods are available, the most commonly practiced is Perturb and Observe so it will be used in our present study [13]-[14]. 2.3.1. Perturb-and-observe (P&O) method The perturb-and-observe (P&O) algorithm is the most commonly used in practice for MPP tracking. It is based on the fact that as the voltage is perturbed and the rate of change of power is observed. Based on the sign (positive or negative) of the derivative , the voltage value is increased or decreased to reach MPP, thereby yielding a zero, derivative. As the nature of this algorithm is absolutely based on perturbation, one can notice some oscillations even after the MPP is reached [13],[15]. Figure 8. Power vs voltage curve showing MPP 2.4. VSC Inverter PV modules generate direct current (DC) and voltage. However, to feed the electricity to the grid, alternating current (AC) current and (AC) voltage are needed. Inverters are the equipment used to convert DC to AC. In addition, they can be in charge of keeping the operating point of the PV array at the MPP. This is usually done with computational MPP tracking algorithms. There are different inverter configurations depending on how the PV modules are connected to the inverter. The VSC converts the 500 V DC link voltages to 260 V AC and keeps power factor at unity. The VSC control system consists of two control loops: a. An external control loop which regulates DC link voltage to +/- 250 V. b. An internal control loop which regulates grid currents (active and reactive) current components. c. The control system uses a sample time of 100 microseconds for voltage and current controllers. Boost and VSC converters with pulse generators use a fast sample time of 1 microsecond in order to get an appropriate resolution of PWM waveforms [16].
  • 7.  ISSN: 2088-8694 IJPEDS Vol. 8, No. 1, March 2017 : 392 – 401 398 3. SIMULATION RESULTS AND DISCUSSION Simulation starts with standard test conditions (25 °C, 1000 W/m²). From t=0 sec to t=0.05 sec, the pulses for boost converters and VSC inverter are blocked. The voltage of PV1 array correspond to the open circuit voltage (5 panels in Series * Voc = 5 * 64.2 = 321 V), and for PV2 array (8 panels in Séries *Voc =8 * 33.2 = 265.6 V) (see Figure 9). At this time the VSC inverter of three-level functions as an uncontrolled rectifier (diode) and the DC capacitors are charged over 500 V (Figure 11). At t = 0.05 s, boost converter and VSC inverter are unlocked. The DC voltage is set at Vd = 500V (see Figure 11). The duty cycles of the two boost converter equal to 0.5 and 0.6 respectively (see Figure 10) irradiance is set at 1000 W/m2 as shown in Figure 12. The nominal speed is reached at t = 0.25s, the voltage generated by the array PV1 is VPV1 = (1-D1) * Vd= (1-0.5) * 500 = 250 V, while the voltage generated by the array PV2 is VPV2 = (1-D2)*Vd = (1-0.6) * 500 = 200 V. Figure 9. Voltage generated by PV1 and PV2 arrays Figure 10. Duty cycles of PV1 and PV2 arrays Figure 11. DC link voltage Vd Figure 12. Irradiance of the PV1 and PV2 arrays The power generated by arrays PV1 and PV2 are on the order of 97 kilowatts and 98 kilowatts respectively, while the maximum powers with irradiance of 1000W/ m² are estimated at 100.7 kilowatts to 100.04 kilowatts (see Figure 13). It is important to note that the voltage and current of phase A at 25 kV busbar are in phase (power factor equals to 1) as shown in Figure 14.
  • 8. IJPEDS ISSN: 2088-8694  Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa) 399 Figure 13. The powers generated by the PV1 and PV2 arrays Figure 14. Current and voltage injected into the grid At t = 0.4 s both MPPT controls are enabled. MPPT1 controller starts controlling the voltage generated by PV1 by acting on the duty cycle of the first boost converter in order to extract the maximum power. The maximum power of the first PV array (100.7 kilowatts) is obtained when the duty cycle D1 equals to 0.453. At t = 0.6 s, the voltage of the array PV1=274 V as expected from the specifications of the PV array (N_série*Vmp = 5 * 54.7 = 273.5 V). From t = 0.7 s to t = 1.2 s, the irradiance Ir1 decreases linearly from 1000 W/m² to 250 W/m². From time t=1.1, the irradiance Ir2 also decreases linearly from 1000 W/m² to 250 W/m² (Figure 16). Both MPPT controllers continue tracking the maximum power delivered by each PV array. At t = 1.2 s when the irradiance Ir1 reaches the value of 250 W/m², the duty cycle D1 is around 0.485. The corresponding voltage and power are 255 V and 22.6 kilowatts respectively. For the second PV array, the irradiance Ir2 reaches the value of 250 W/m² at t = 1.65 s, where the duty cycle D2=0.6. Note that tracking the maximum power point by the MMPT controller is ensured even when the irradiance changes rapidly. From t = 1.5 s to t = 3 s various changes of the irradiance Ir1 and Ir2 are applied to illustrate the good performance of the MPPT controller. Figure 15. Power generated by the PV1 and PV2 arrays Figure 16. Irradiance of the two arrays
  • 9.  ISSN: 2088-8694 IJPEDS Vol. 8, No. 1, March 2017 : 392 – 401 400 Figure 17. Duty cycles of the PV1 and PV2 arrays Figure 18. Voltage generated by the PV1 and PV2 arrays Figure 19 shows the power injected into the grid. From t = 0 s to t = 0.05 s the power injected into the grid is growing because the pulses of boost converter and VSC inverter are blocked. At t = 0.05s the pulses are enabled, the power injected into the grid is 195 kW. From t = 0.2 s to t = 0.75 s the irradiance is 1000W / m², while the injected power reaches its maximum value. From t = 0.75 s to t = 2.75 s several variations in the irradiance lead to change the power injected into the grid to stabilize at 2.75 s and takes the value of 200 kilowatts. Figure 19. Power injected into the grid 4. CONCLUSION This paper presents the modeling and simulation of grid connected PV system with Perturb and Observe MPPT Algorithm to inject the power extracted from a photovoltaic array and obtain unitary power factor in varying weather conditions. According to the results obtained from the simulation, we can say that it is essential to operate the system at the MPP (Maximum Power Point) of a PV array, in other words we should always extract the maximum power from the PV module by modulating the duty cycle of the boost converter in order to enhance the power injected into the grid, otherwise the PV array is not fully exploited which consecontly is reflected by a higher losses in the energy transferred from the PV array to the utility grid. Also the Pulse width modulation (PWM) technique has been developed beside inverters. So that we can obtain a sinusoidal waveform at the output of the inverter and the total harmonic distortion (THD) of the output voltage can be reduced.The results confirm the adequate performance of whole designed control. REFERENCES [1] K. S. Srikanth, “A Three Phase Multi Level Converter for Grid Connected PV System,” International Journal of Power Electronics and Drive System (IJPEDS), vol/issue: 5(1), pp. 71-75, 2014. [2] M. C. Mira, et al., “Boost Converter With Combined Control Loop for a Stand-Alone Photovolainc Battery Charge System,” IEEE 14th Workshop On Control and Modeling Power electronics, 2013. [3] “Photovoltaic Cell Conversion Efficiency,” U.S. Department of Energy, Retrieved, 19 May 2012. [4] D. Sera, et al., “On the Perturb-and-Observe and Incremental Conductance MPPT Methods for PV Systems,” IEEE Journal of Photovoltaics, vol/issue: 3(3), pp. 1070-1078, 2013.
  • 10. IJPEDS ISSN: 2088-8694  Modeling and Simulation of Grid Connected PV Generation System Using .... (Omar Mohammed Benaissa) 401 [5] F. Liu, et al., “Variable Step Size INC MPPT Method for PV Sytems,” IEEE Transactions on Industrial Electronics, vol/issue: 55(7), 2008. [6] T. F. Wu, et al., “A Fuzzy Logic-Controlled Single Stage Converter for PV-Powred Lighting System Applications,” IEEE Transactions on Industrial Electronics, vol/issue: 47(2), pp. 287–296, 2000. [7] M. Veerachary, et al., “Neural-Network Based Maximum Power Point Tracking of Coupled-Iductor Interleaved- Boot Converter Supplied PV System Using Fuzzy Controller,” IEEE Transactions on Industrial Electronics, vol/issue: 50(4), pp. 749-758, 2003. [8] P. H. Zope, et al, “Performance and Simulation Analysis of Single-Phase Grid Connected PV System Based on Z- Source Inverter,” in International conference on Power Electronics, Drives and Energy System, 2010. [9] S. Li, et al, “A Novel Maximum Power Point Tracking Control Method With Variable Weather Parameters for Photovoltaic Systems,” (ELSEVIER), Solar Energy, vol. 97, pp. 529-536, 2013. [10] A. A. Siddik and M. Shangeetha, “Implimentation of Fuzzy Logic Controller in photovoltaic Power generation using Boost converter and Boost Inverter,”International Journal of Power Electronics and Drive System (IJPEDS), vol/issue: 2(3), pp. 249-256, 2012. [11] G. E. Saady, et al., “Performance of Photovoltaic Water Pumping System under Different MPPT Algorithms,” in 17th International Middle –East power system Conference, 2015. [12] R. Teodorescu and M. Liserre, “Power Electronics for Renewable Energy,” Slides presented at the course PERES, 2006. [13] J. J. Nedumgatt, et al., “Perturb and Observe MPPT Algorithm for Solar PVSystems-Modeling and Simulation,” in Annual IEEE India Conference, pp. 1-6, 2011. [14] K. Manohar and P. S. Rani, “MPPT and Simulation for a Grid-Connected Photovoltaic System and Fault Analysis,” International Journal of Engineering And Science (IJES), pp. 158-166, 2013. [15] M. D Singh and K. B Khanchandani, “Power Electronics,” Tata Mcgraw Hill publishers, 2nd edition, pp. 135-670, 2011. [16] J. Kasera, et al, “Design of grid connected Photovoltaic System Employing Incrimental Conductance MPPT Algorithm,” Journal of Electrical Engeneering.